Microlife BP AG1-40

Microlife · BP

BP AG1-40

Release date not published

A manual upper-arm blood pressure kit with a combined palm gauge and hand pump, professional cuff and supplied stethoscope.

Type
Upper arm
Users
–
App
No
Validated
–

Measuring

Type
Upper arm
Irregular heartbeat detection
No
AFib detection or ECG
No
Method
Fully manual auscultatory upper-arm measurement using the supplied stethoscope and aneroid gauge. Combined palm dial and pumping ball with adjustable deflation valve; no electronic calculation. Actual first retail date unresolved
Accuracy
January 2024 guide gives 0–300 mmHg range, 2 mmHg scale divisions, static accuracy within ±3 mmHg and air leakage under ±4 mmHg/min. Guide has conflicting maintenance wording, at least six-monthly recalibration versus two-year accuracy testing; follow the exact applicable service advice rather than treating these as one interval
Clinical validation
Guide cites EN ISO 81060-1 and ANSI/AAMI SP09. These standards do not establish independent clinical validation; exact independent validation unresolved and headline omitted
Features
Mechanical palm dial and hand pump with adjustable valve; supplied stethoscope used to hear Korotkoff sounds. No automatic pulse calculation, irregular-heartbeat screening, AFib detection or ECG

Cuff

Cuff fits
25.4–40.6 cm
Cuff
Current exact guide specifies supplied 25.4–40.6 cm cuff. Manufacturer product page describes a professional cuff without metal bar and rounds fit to 25–40 cm

Connections and memory

Bluetooth and app
No
Memory
No electronic storage; readings and date/time recorded separately by the operator
App
No Bluetooth, USB or phone app
Power
Mechanical operation without batteries or mains power

Design

Display details
Analogue manometer with pointer; no LCD
Size
Global product/support pages list 170 × 65 × 105 mm and 520 g. January 2024 exact guide instead lists 175 × 70 × 103 mm and 500 g; maker does not resolve the discrepancy or separate component weights
In the box
Exact guide lists cuff, pump ball, valve, stethoscope and soft bag; manometer is identified in controls

Pros and cons

Pros

  • No batteries required
  • Stethoscope supplied
  • Gauge and pump combined for palm operation

Cons

  • Requires manual listening and reading
  • No electronic memory or app
  • Manual inflation and deflation

Closest rivals

Model
TypeUsersAppValidatedReleased
Upper arm–No––
Upper arm–No––
Upper arm–No––

Sources

  1. microlife.com/consumer-products/blood-pressure/aneroid-devices/bp-ag1-40
  2. microlife.com/support/blood-pressure/bg-ag1-40
  3. microlife.com/media/303/download/IB%20AG1-40%20S%26E-V15%200724.pdf
  4. microlife-asiapacific.com/consumer-products/aneroid-devices/bp-ag1-40

Photo: Microlife official exact-model product/support photograph; BP AG1-40 monitor and supplied measurement assembly. Complete supplied canvas, background and alpha retained.

Spot a mistake? Tell us