Beurer BM 85 vs Beurer BM 96 Cardio

Every spec side by side, from each maker's published figures.

Better figure, where one is clearly better

BM 85 compared with BM 96 Cardio
BeurerBM 85BeurerBM 96 Cardio
Overview
Released2014–
Measuring
TypeUpper armUpper arm
Irregular heartbeat detectionYesYes
AFib detection or ECGNoYes
MethodAutomatic oscillometric upper-arm measurement during inflation; exact UK item 65803. July 2014 retail test establishes the sale year; first-sale month unconfirmedAutomatic oscillometric upper-arm blood pressure measurement during inflation; separate single-channel ECG stick. Exact BM 96 Cardio item 65801. Maker announcement dated 31 August 2021 does not establish the first retail date, which remains unconfirmed
AccuracyMaker display accuracy ±3 mmHg for systolic and diastolic pressure and ±5% for pulse; systolic range 60–260 mmHg, diastolic 40–199 mmHg and pulse 40–180 beats/minute. Cuff-pressure range 0–300 mmHg is separateMaker display accuracy ±3 mmHg for systolic and diastolic pressure and ±5% for pulse; systolic range 60–280 mmHg, diastolic 30–200 mmHg and pulse 30–199 beats/minute. Cuff-pressure range 0–300 mmHg is separate. ECG bandwidth 0.05–40 Hz and sample rate 500 Hz
Clinical validationMaker datasheet claims technical identity with BP3ESH5 and ESH validation. Medaval records a specific-population study using a non-standard protocol and unpublished internal DHL data; independent standard-protocol exact-device validation not established, so headline flag omittedIndependently published exact-device blood pressure validation not established; Medaval reports no peer-reviewed validation information for this technology, so headline validation flag omitted
FeaturesIrregular-heartbeat warning, coloured LED classification scale, HSD haemodynamic resting indicator and cuff holder. No ECG or dedicated AFib screening; current UK table says no electronic cuff-fit checkAFib detection, irregular-heartbeat warning, cuff-fit check, two measurement reminders, coloured classification scale and HSD haemodynamic resting indicator. ECG recordings can be 30, 60, 90 or 120 seconds; status indications include OK, AFib, heart rate below 60 bpm or above 100 bpm. Chest/finger methods approximate leads II or III; hand-to-hand method approximates lead I and has lower stability. These are alternative single-channel positions, not simultaneous three-lead recording; the maker's doctor annex excludes full clinical or emergency diagnosis
Cuff
Cuff fits22–42 cm22–42 cm
CuffCurrent maker manual and UK bundle specify 22–42 cm circumference. Technik zu Hause's 2014 tested bundle supplied a 22–36 cm cuff with a separate optional 35–44 cm cuff; current supplied cuff is not inferred from the old reviewUpper-arm cuff for 22–42 cm circumference; correct cuff placement and resting conditions are still required
Connections and memory
Users22
Readings stored60 per user60 per user
Bluetooth and appYesYes
MemoryTwo users with 60 dated readings each; oldest overwritten when full. Averages of all stored readings and morning/evening readings over the latest seven days. Deletion clears the entire selected user memory; individual readings cannot be deletedTwo users with up to 60 dated blood pressure readings each; oldest overwritten when full. Averages of all stored readings and morning/evening readings over the latest seven days. ECG memory holds up to 60 recordings per user at 30 seconds; longer recordings can reduce capacity. Deleting memory clears the selected user history
AppBluetooth Low Energy transfer to beurer HealthManager Pro; USB transfer uses the HealthManager Pro USB uploader and permits app/web viewing. Current manual states compatibility with Bluetooth 4.0 smartphones/tablets; the 2021 datasheet lists Bluetooth 5.0 among supported-device requirements, not an exact monitor radio versionBluetooth Low Energy transfer to beurer HealthManager Pro. The maker's October 2022 datasheet also specifies web software and USB uploader; these are separate from Bluetooth transfer. Current manual gives compatibility with Bluetooth 4.0 or later, not an exact radio version. Optional MyCardio Pro analysis service is described separately on the product page
PowerBuilt-in 3.7 V / 400 mAh lithium-ion battery; approximately 50 measurements per charge depending on blood pressure and pump pressure. USB charging from PC or supplied USB mains part; minimum two-hour recharge instruction when depleted. This is rechargeable battery operation, despite the web table's mains-operated labelFour 1.5 V AA batteries included; approximately 300 measurements depending on blood pressure, inflation pressure and ECG recording duration
Design
Display detailsIlluminated LCD with black digits, maker 7.0 × 6.5 cm; illuminated sensor touch controls, date/time and battery level. IPX0 according to manualIlluminated LCD with black digits, maker 10.4 × 6.7 cm; four sensor touch buttons, illuminated start/stop button, date/time and battery indicator. IP21
SizeManual 180 × 99 × 40 mm (L × W × H), approximately 456 g with cuff. Datasheet also gives 456 g but says without batteries despite the built-in cell. Web table gives 51 mm height and 638 g excluding packaging without comparable conditions; retained as source differencesBlood pressure unit 120 × 144 × 53 mm (L × W × H), approximately 490 g without batteries and with cuff; ECG stick approximately 40 g and 22 mm diameter × 120 mm height. Web table's 744 g excluding packaging lacks the same weighing conditions and is not substituted for the manual values
In the boxMonitor, cuff, cuff holder, USB cable, USB mains part and storage pouch; instructions and quick-start guide available from maker. Regional supplied plug differs; current UK table identifies Euro plugBlood pressure unit, cuff, ECG stick, four AA batteries, storage pouch, instructions, quick-start guide and annex for the attending doctor, as listed in the May 2026 manual; UK product page additionally lists a USB transfer cable and blood pressure record