Beurer BC 21 vs Microlife BP W90

Every spec side by side, from each maker's published figures.

Better figure, where one is clearly better

BC 21 compared with BP W90
BeurerBC 21MicrolifeBP W90
Overview
Released––
Measuring
TypeWristWrist
Irregular heartbeat detectionYesYes
AFib detection or ECGNoNo
MethodAutomatic oscillometric wrist measurement during deflation. Exact UK item 65046, EAN 4211125650469; SK2 voice-language version. First-sale date unconfirmedAutomatic oscillometric wrist measurement during deflation; the October 2021 manual describes inflation followed by gradual pressure reduction. First on-sale date unresolved
AccuracyExact manual display accuracy ±3 mmHg for systolic and diastolic pressure and ±5% for pulse. Systolic range 60–260 mmHg, diastolic 40–199 mmHg and pulse 40–180 beats/minute; cuff-pressure range 0–300 mmHg is separateStatic pressure accuracy ±3 mmHg and pulse ±5% of readout. October 2021 manual gives blood pressure 20–280 mmHg and pulse 40–200 bpm; current support instead lists systolic 60–255 and diastolic 40–200 mmHg. Cuff-pressure display 0–299 mmHg is separate
Clinical validationExact manual gives an unspecified clinical-test maximum permissible standard deviation of 8 mmHg, without identifying a published study. Medaval reports no peer-reviewed clinical validation information for BC 21, but incorrectly labels its measurement site upper arm; exact maker manual establishes wrist measurement. Independently established headline validation omittedMaker claims BIHS validation through the measuring technology of BP 3BZ1-3. Medaval reports no published exact-model peer-reviewed validation found; headline validation remains unresolved rather than treating the related-model claim as an exact W90 trial
FeaturesSpoken instructions and results in German, English, French, Italian or Turkish for UK item 65046; three volume levels or off. Shared data sheet separately lists item 65040 with English, Spanish, Polish, Arabic and Farsi; those languages are not part of this UK version. Irregular-heartbeat warning, coloured classification scale, date/time, application-error messages and automatic switch-off. No dedicated AFib screening, ECG, movement detection, heart-level position or resting indicatorOrdinary irregular-heartbeat indication, audible measurement signals, two independently enabled daily reminder alarms, low-battery warning and automatic switch-off after approximately one minute. No dedicated AFib screening or MAM sequence established
Cuff
Cuff fits14–19.5 cm13.5–21.5 cm
CuffAttached wrist cuff for 14–19.5 cm circumference. User must position the cuff at heart level; no electronic position guidanceWrist circumference 13.5–21.5 cm in exact October 2021 manual
Connections and memory
Users22
Readings stored60 per user99 per user (better)
Bluetooth and appNoNo
MemoryTwo users with 60 dated readings each; oldest overwritten when full. Average of all stored values and morning (05:00–09:00) or evening (18:00–20:00) readings over the latest seven days. Deletion clears the selected user's entire memoryUp to 99 dated readings for each of two user profiles; guest mode does not store readings. Time-button and memory-button sequence selects the user. Oldest reading overwritten when full; stored readings retained after cell replacement, while clock and alarms reset. History can be cleared for the selected user. Instructions establish individual recall, not an automatic average
AppNo Bluetooth or connection from the monitor. Current Scan & Save support captures displayed values using a smartphone camera into beurer HealthManager Pro; not automatic transfer–
PowerTwo 1.5 V LR03 AAA alkaline batteries; approximately 200 measurements depending on blood pressure and inflation pressure. Battery operation onlyTwo 1.5 V AAA alkaline cells, approximately 460 measurements with new batteries. NiMH cells supported with external charging. Polish product page's table says four AAA cells and DC 6 V, conflicting with its own two-cell package list and the exact manual; copied table is not adopted and no adapter interface is assigned
Design
Display detailsNon-illuminated LCD with black digits, maker size 3.8 × 4.5 cm. Physical membrane memory and start/stop controls; low-battery indicator. Manual IP22LCD with ON/OFF, memory and time buttons; IP20 in October 2021 manual
SizeExact manual and September 2021 data sheet give 87 × 67 × 31 mm (L × W × H) and approximately 105 g without batteries; data sheet specifies cuff included. Current product table instead gives 87 × 67 × 70 mm and 187 g excluding packaging, with weighing conditions unspecified; differences unresolved68 × 68 × 70 mm including cuff in current support; 140 g including batteries
In the boxMonitor with attached cuff, two AAA batteries, storage box and instructions. Current product page also lists a blood pressure recordMonitor, storage box, two AAA alkaline batteries and blood-pressure diary listed by Polish maker page. Product resource is Polish; support and operating instructions include English. Photographs show distinct green-front and silver-front maker finishes, without inventing additional hardware configurations