Beurer BM 48 vs Microlife BP B1 BT

Every spec side by side, from each maker's published figures.

Better figure, where one is clearly better

BM 48 compared with BP B1 BT
BeurerBM 48MicrolifeBP B1 BT
Overview
Released––
Measuring
TypeUpper armUpper arm
Clinically validated–Yes
Irregular heartbeat detectionYesYes
AFib detection or ECGNoNo
MethodAutomatic oscillometric upper-arm measurement during inflation. Exact UK item 10350, EAN 4211125103507; manual model BM 48, technical type BM 48/1. Announced at IFA on 6 September 2024 with planned German availability from October 2024; actual first sale unresolvedAutomatic oscillometric upper-arm measurement during deflation; technical model BPHJA2-B, reference BP B1 BT. Gentle+ optimises inflation pressure and deflation speed. First on-sale date unresolved
AccuracyManual display accuracy ±3 mmHg for systolic and diastolic pressure and ±5% for pulse; systolic range 50–280 mmHg, diastolic 30–200 mmHg and pulse 40–199 beats/minute. Maximum cuff pressure 300 mmHg is separateStatic pressure accuracy ±3 mmHg and pulse ±5% of readout; systolic 60–255 mmHg, diastolic 40–200 mmHg and pulse 40–199 beats/minute. Cuff-pressure display 0–299 mmHg is separate
Clinical validationCurrent manual claims clinical testing to ISO 81060-2. Independent validation for exact current item 10350 not established; headline flag omittedExact STRIDE BP listing approves equivalence to BP B3 AFIB, whose adult ISO 81060-2:2018 validation study was published in 2021; cuff 22–42 cm. This is approved equivalence rather than a separate exact-model trial. Manufacturer UK page also cites inherited BIHS A/A claim
FeaturesIrregular-heartbeat warning, coloured classification scale, cuff-position check and HSD resting indicator. Automatic switch-off after approximately one minute and low-battery indicator. Single START/STOP button; no ECG, dedicated AFib screening or voice outputOrdinary irregular-heartbeat indication, cuff-fit check, arm-movement and cuff-pressure error warnings, three-level reading scale, low-battery indication and automatic switch-off after approximately one minute. No dedicated AFib algorithm or automatic triple-measurement sequence established by exact instructions
Cuff
Cuff fits22–42 cm22–42 cm
CuffSupplied conventional universal cuff for 22–42 cm upper-arm circumference, replacement item 110.031; no easyClip or easyLock mechanismSupplied soft non-washable M–L cuff fits 22–42 cm; compatible cuff and connector required. Replacement cuffs must use the supplied matching connector. Spot-clean cuff with damp cloth; no machine or dishwasher washing
Connections and memory
Readings stored–30
Bluetooth and appYesYes
MemoryNo calculated averages according to the product table. Complete operation section supplies Bluetooth settings but no on-device recall, user-selection or clock-setting controls. Website date/time claim and isolated saved-measurement/user paragraphs conflict with those controls; memory and user counts unresolved. Reading history is available through the appStores up to 30 readings with date/time and displays their average; oldest overwritten when full. New reading can be excluded, but saved history clears as a whole. Memory erased on battery removal. Manual pairing text refers to user selection 1/2 but exact controls have no user selector or separate per-user capacity; headline user count omitted
AppBluetooth transfer to beurer HealthManager Pro; app stores readings and provides export. Automatic transmission can be enabled or disabled using a long press while the monitor is off. Manual publishes 2400–2483 MHz radio band and maximum 5 dBm transmission power, without a Bluetooth versionBluetooth 5.0 (European manufacturer page), Bluetooth Low Energy (manual), transfers readings to Microlife Connected Health+ on Android/iOS. Wireless transfer starts after measurement or with Bluetooth/time button and switches off after two minutes without a connection. USB-C is a power input, not an established wired data connection
PowerFour included 1.5 V LR03 AAA batteries; approximately 300 measurements depending on blood pressure, inflation pressure and number of Bluetooth connections. Optional USB-C mains input 5 V DC / 1 A; remove batteries for mains use. Not battery charging. Manual EU adapter 072.78 and UK adapter 072.79Four 1.5 V LR3 AAA alkaline batteries, approximately 400 measurements. Rechargeable NiMH cells supported but must be removed and charged externally. Optional USB-C adapter model DSA-5PF21-05, 100–240 V input and 5 V 1 A 5 W output; batteries are not charged by the monitor
Design
Display detailsIlluminated inverse LCD with white digits on black; maker display size 6.2 × 6.2 cm. Manual IP20LCD, ON/OFF, memory and Bluetooth/time controls; IP21 according to current exact manual
SizeAugust 2026 manual 128 × 91 × 46 mm (L × W × H), approximately 357 g with cuff and without batteries. Current website and datasheet give 130 × 91 × 46 mm and 397 g excluding packaging, without defining battery/cuff weighing conditions130 × 93.5 × 52 mm; 240 g including batteries
In the boxMonitor, universal 22–42 cm cuff, four AAA batteries and instructions. Mains adapter sold separatelyMonitor, soft 22–42 cm cuff and four AAA batteries listed by UK manufacturer. Mains adapter optional