Beurer BM 38 vs Microlife BP 3AS1-2

Every spec side by side, from each maker's published figures.

Better figure, where one is clearly better

BM 38 compared with BP 3AS1-2
BeurerBM 38MicrolifeBP 3AS1-2
Overview
Released––
Measuring
TypeUpper armUpper arm
Clinically validated–Yes
Irregular heartbeat detectionYesNo
AFib detection or ECGNoNo
MethodAutomatic oscillometric upper-arm measurement during inflation. UK item 10361, EAN 4211125103613; manual model BM 38, technical type BM 48/1. Announced at IFA on 6 September 2024 with planned German availability from October 2024; first actual sale unresolvedSemi-automatic oscillometric upper-arm measurement with capacitive pressure sensor. Hand inflation using pump integrated into handle; automatic deflation and digital pressure/pulse results. O/I button interrupts measurement and releases cuff pressure. Actual first retail date unresolved
AccuracyManual display accuracy ±3 mmHg for systolic and diastolic pressure and ±5% for pulse; systolic range 50–280 mmHg, diastolic 30–200 mmHg and pulse 40–199 beats/minute. Maximum cuff pressure 300 mmHg is separateFebruary 2024 exact guide gives systolic/diastolic range 20–280 mmHg, pulse 40–200 bpm, 1 mmHg pressure resolution, static pressure accuracy ±3 mmHg and pulse accuracy ±5% of reading
Clinical validationCurrent manual claims clinical testing to ISO 81060-2. Independent exact-device validation not established in the source pass; headline flag omittedNathan and colleagues, Blood Pressure Monitoring 2015, tested exact Microlife 3AS1-2 in 45 pregnant women including 15 with pre-eclampsia. Overall B/A grade under the British Hypertension Society protocol and passed the study's ISO mean-difference standard; pregnancy-only subgroup A/A. These are study-specific findings, not evidence for every population named in generic maker text
FeaturesIrregular-heartbeat warning, coloured classification scale, cuff-position check and HSD resting indicator. Automatic switch-off after approximately one minute, battery indicator and START/STOP button. No ECG, dedicated AFib screening or voice outputManual inflation, automatic measurement/deflation, low-battery and inflation indicators. Flashing heart indicates detected pulse, not irregular-heartbeat screening. No AFib detection, ECG or automatic triple-measurement mode
Cuff
Cuff fits22–42 cm22–32 cm
CuffSupplied conventional universal cuff for 22–42 cm upper-arm circumference, replacement item 110.031; no easyClip or easyLock mechanismSupplied M 22–32 cm cuff; optional L 32–42 cm. Single-tube cuff with T-connector attaches at the back of the device
Connections and memory
Users–1
Readings stored–1
Bluetooth and appNoNo
MemoryProduct table says no calculated averages. No reading-recall, user-selection or clock-setting controls established by the complete operating instructions. Website date/time claim and manual's isolated saved-measurement/user paragraphs conflict with the controls; stored memory and user counts left unresolvedOne latest measurement retained until the next measurement or battery removal. Hold O/I for at least three seconds to recall. No dated history, user selector or averaging
AppScan & Save photographs the display into beurer HealthManager Pro. No Bluetooth connection from the monitor; smartphone-camera capture is separate from wireless transmissionNo Bluetooth, USB or phone-app transfer
PowerFour included 1.5 V LR03 AAA batteries; approximately 300 measurements depending on blood pressure and inflation pressure. USB-C input supports optional 5 V DC / 1 A mains operation, not battery charging. Remove batteries for mains operation; manual lists EU adapter 072.78 and UK adapter 072.79Two 1.5 V AAA alkaline cells; approximately 780 measurements using new batteries. Current guide does not recommend 1.2 V rechargeable cells. Generic guarantee wording about an optional adaptor does not establish a mains socket or mains operation
Design
Display detailsNon-illuminated LCD with black digits; maker display size 6.2 × 6.2 cm. Manual IP20LCD showing systolic, diastolic and pulse readings; single O/I button. IP20
SizeAugust 2026 manual 128 × 91 × 46 mm (L × W × H), approximately 357 g with cuff and without batteries. Current website and datasheet give 130 × 91 × 46 mm and approximately 385 g excluding packaging, without defining battery/cuff weighing conditions68 × 186 × 48.5 mm (width × length × height); 310 g including batteries, excluding cuff in global support table
In the boxMonitor, universal 22–42 cm cuff, four AAA batteries and instructions. Mains adapter sold separatelyExact guide establishes monitor with integrated pump and M 22–32 cm cuff; complete regional accessory list unresolved

More comparisons