Beurer BC 28 vs Microlife BP W3 Comfort
Better figure, where one is clearly better
| BeurerBC 28 | MicrolifeBP W3 Comfort | |
|---|---|---|
| Overview | ||
| Released | – | – |
| Measuring | ||
| Type | Wrist | Wrist |
| Clinically validated | – | Yes |
| Irregular heartbeat detection | Yes | Yes |
| AFib detection or ECG | No | No |
| Method | Automatic oscillometric wrist measurement during deflation. Exact white UK item 65044, EAN 4211125650445; BC 27 dark-grey item 65904 has a separate maker product record. First-sale date unconfirmed | Automatic oscillometric wrist measurement during inflation with Comfort+; exact current European manual identifies BP3KB1-3E. First on-sale date unresolved |
| Accuracy | Exact manual display accuracy ±3 mmHg for systolic and diastolic pressure and ±5% for pulse. Systolic range 60–260 mmHg, diastolic 40–199 mmHg and pulse 40–180 beats/minute; cuff-pressure range 0–300 mmHg is separate | Static pressure accuracy ±3 mmHg and pulse ±5% of readout. Current European manual gives systolic 60–255 mmHg, diastolic 40–200 mmHg and pulse 40–199 bpm; older UK manual gives 20–280 mmHg blood pressure and 40–200 bpm. Cuff-pressure display 0–299 mmHg is separate |
| Clinical validation | Manual gives an unspecified clinical-test maximum permissible standard deviation of 8 mmHg for systolic and diastolic pressure, without identifying a published study. Medaval reports no peer-reviewed clinical validation information for BC 28; headline independently established validation omitted | STRIDE BP approves equivalence to W2 Slim, whose 2016 adult validation used ESH-IP 2010 and ANSI/AAMI/ISO 2013; not a separate published W3 Comfort trial. STRIDE lists a 13.5–23 cm cuff. Manufacturer BIHS A/A marketing and current manual ESH/ISO wording are retained as claims, not additional independent trials |
| Features | Irregular-heartbeat warning, coloured classification scale, date/time, application-error messages and automatic switch-off after approximately one minute. No dedicated AFib screening, ECG, movement detection, heart-level position indicator, resting indicator or voice output | Ordinary irregular-heartbeat indication, cuff-fit check, arm-movement warning, single-colour blood-pressure classification scale, low-battery indicator and automatic switch-off after approximately one minute. No dedicated AFib algorithm, MAM sequence or electronic wrist-position sensor established |
| Cuff | ||
| Cuff fits | 14–19.5 cm | – |
| Cuff | Attached wrist cuff for 14–19.5 cm circumference. User must position the cuff at heart level; no electronic position guidance | UK product page and its EN-FR 4119 manual give 13.5–23 cm and a soft D-ring wrist cuff. European August 2026 manual instead gives 13.5–21.5 cm despite the European product page still advertising 23 cm. Headline cuff range omitted pending exact supplied revision confirmation; no inferred second hardware model |
| Connections and memory | ||
| Users | 2 | – |
| Readings stored | 60 per user (better) | 30 |
| Bluetooth and app | No | No |
| Memory | Two users with 60 dated readings each; oldest overwritten when full. Average of all stored values and morning (05:00–09:00) or evening (18:00–20:00) readings over the latest seven days. Deletion clears the selected user's entire memory | Stores 30 readings with date/time and displays average of all stored readings, excluding suboptimal cuff fit; not specifically the last three. Oldest overwritten when full. Readings retained on cell replacement, clock reset. New reading can be excluded; saved history clears together. Exact controls establish no separate user selector |
| App | No Bluetooth or connection from the monitor. Current Scan & Save support captures the displayed values using a smartphone camera into beurer HealthManager Pro; not automatic transfer | – |
| Power | Two 1.5 V LR03 AAA alkaline batteries; exact manuals claim approximately 170 measurements depending on blood pressure and inflation pressure, while the current product table says approximately 300. Battery operation only | Two 1.5 V AAA alkaline cells; approximately 320 measurements with new cells. NiMH cells supported but must be removed and charged externally |
| Design | ||
| Display details | Non-illuminated LCD with black digits, maker size 3.5 × 4.0 cm. Physical start/stop and memory controls; low-battery indicator. Manual IP22 | LCD with ON/OFF, memory and time controls. Older UK manual gives IP20; current European August 2026 revision gives IP22. Revision conflict retained rather than assuming an upgrade applies to every unit |
| Size | Exact English and March 2022 multilingual manuals and January 2019 data sheet give 84 × 60 × 29 mm (L × W × H), approximately 92 g with cuff without batteries. Current product table instead gives 60 × 84 × 55 mm and 171 g excluding packaging, with weighing conditions unspecified; differences unresolved | 81 × 65 × 21 mm; 112 g including batteries |
| In the box | Monitor with attached cuff, two AAA batteries, storage box and instructions. Current product page also lists a blood pressure record. Dedicated English manual's footer is September 2019 despite its download filename using March 2022; newer multilingual manual has the same core specifications | Monitor, storage case, two AAA alkaline batteries, instructions and blood-pressure diary. Current range listing establishes catalogue presence, not worldwide stock or first-sale date |
More comparisons
- Beurer BC 28 vs Microlife BP W1 Basic
- Beurer BC 28 vs Microlife BP W10 Basic
- Beurer BC 28 vs Microlife BP W2 Slim
- Beurer BC 21 vs Microlife BP W3 Comfort
- Beurer BC 27 vs Microlife BP W3 Comfort
- Beurer BC 28 vs Microlife BP W70
- Beurer BC 28 vs Microlife BP W90
- Beurer BC 28 vs Omron RS1
- Beurer BC 28 vs Omron RS2
- Beurer BC 28 vs Omron RS4

