Beurer BM 64 vs Omron M7 Intelli IT

Every spec side by side, from each maker's published figures.

Better figure, where one is clearly better

BM 64 compared with M7 Intelli IT
BeurerBM 64OmronM7 Intelli IT
Overview
Released––
Measuring
TypeUpper armUpper arm
Clinically validated–Yes
Irregular heartbeat detectionYesYes
AFib detection or ECGYesYes
MethodAutomatic oscillometric upper-arm measurement during inflation. UK item 65400, EAN 4211125654009; manual type BM 64. Announced on 12 November 2023 with planned German availability from March 2024; actual first-sale date unresolvedOscillometric upper-arm measurement; HEM-7361T-EBK, distinct from earlier M7 Intelli IT HEM-7322T-E and newer M7 Intelli IT AFib HEM-7380T1-EBK. First on-sale date not established
AccuracyManual display accuracy ±3 mmHg for systolic and diastolic pressure and ±5% for pulse. Systolic range 50–280 mmHg, diastolic 30–200 mmHg and pulse 40–199 beats/minute; maximum cuff pressure 300 mmHg is separateMaker's pressure accuracy ±3 mmHg and pulse accuracy ±5%; systolic range 60–260 mmHg, diastolic 40–215 mmHg and pulse 40–180 beats/minute
Clinical validationCurrent manual claims clinical testing to ISO 81060-2; independent validation for this exact model not established. The shared launch release's pregnancy-validation claim belongs to BM 53, not BM 64Maker claims adult, pregnancy/preeclampsia and type II diabetes validation. Medaval attributes BIHS/STRIDE recommendations to BP760N HEM-7320-Z equivalence, but says the unpublished assessment cannot be verified against MDR requirements; this does not establish diagnostic accuracy of rhythm indicators
FeaturesAdvanced arrhythmia detection flags possible atrial fibrillation, without recording an ECG. Coloured classification scale, cuff-position check, HSD resting indicator and low-battery indication. Maker retains triple-measurement mode; May 2024 instructions describe three measurements with 30-second waits and a final average, while September 2026 instructions omit that operation sectionSelectable AFib screening takes three readings 30 seconds apart and displays their average; not ECG recording or diagnosis despite the web category BPM & ECG. Ordinary readings use a separate irregular-heartbeat indicator. Cuff-wrap, movement and high-pressure indicators
Cuff
Cuff fits22–42 cm22–42 cm
CuffSupplied premium cuff fits upper-arm circumferences of 22–42 cm; conventional tube connection, not easyClip or easyLockHEM-FL31 Intelli Wrap cuff for 22–42 cm arms
Connections and memory
Users22
Readings stored120 per user (better)100 per user
Bluetooth and appYesYes
MemoryTwo separately selected users with 120 readings each; oldest reading replaced when full. Recall individual readings and average of all stored readings, plus morning (05:00–09:00) and evening (18:00–20:00) averages over the last seven days. Date/time and user-selection slider explicitly described in the manual100 readings per user for two users; guest readings are unsaved and do not offer AFib screening. Latest two/three readings within ten minutes can be averaged, plus morning/evening weekly averages; dual display compares readings
AppBluetooth transfer to beurer HealthManager Pro with automatic transfer configurable on the monitor; six-digit pairing PIN. Manual publishes 2400–2483 MHz band and maximum 5 dBm transmission power, without a Bluetooth versionBluetooth Low Energy transfer to OMRON connect; Bluetooth can be disabled
PowerFour included 1.5 V LR6 AA batteries; approximately 300 measurements depending on blood pressure, inflation pressure and Bluetooth connections. Optional USB-C mains supply 5 V DC / 1 A; remove batteries for mains use. Included USB-C cable does not charge batteriesFour AA batteries included; optional AC adapter. Approximately 1000 measurements with new alkaline batteries, fewer in three-reading AFib mode
Design
Display detailsIlluminated inverse XL LCD with white digits on black; four sensor touch buttons and a central START/STOP control. Manual IP20Digital LCD; monitor IP20, not the optional adapter's IP21/IP22
Size143 × 105 × 60 mm (L × W × H). Manual and datasheet approximately 450 g with cuff and without batteries; current UK website lists 646 g excluding packaging without specifying cuff/battery weighing conditionsApproximately 191 × 85 × 120 mm (W × H × L); 460 g without batteries
In the boxMonitor, 22–42 cm premium cuff, four AA batteries, USB-C cable, storage pouch and instructions; mains adapter optionalMonitor, HEM-FL31 cuff, four AA batteries, instructions 1/2, setup instructions and storage case