A&D Medical UA-611 vs Microlife BP A3 PC
Better figure, where one is clearly better
| A&D MedicalUA-611 | MicrolifeBP A3 PC | |
|---|---|---|
| Overview | ||
| Released | – | – |
| Measuring | ||
| Type | Upper arm | Upper arm |
| Clinically validated | – | Yes |
| Irregular heartbeat detection | Yes | Yes |
| AFib detection or ECG | – | No |
| Method | Automatic oscillometric measurement with fuzzy-logic-controlled inflation; designed for adult home use; first on-sale date not established | Oscillometric upper-arm measurement during deflation. Side switch selects a single measurement or MAM mode, which analyses three readings with 15-second pauses into one displayed result. Individual MAM results are not displayed; a fourth measurement is taken if one is questionable. First actual on-sale date unresolved |
| Accuracy | Maker specification ±3 mmHg pressure and ±5% pulse; pressure range 0–299 mmHg, systolic 60–279 mmHg, diastolic 40–200 mmHg and pulse 40–180 beats/min | Exact April 2020 English/Greek guide gives blood pressure 20–280 mmHg, pulse 40–200 bpm, static accuracy ±3 mmHg and pulse accuracy ±5%. Current global support instead separates systolic 60–255 and diastolic 40–200 mmHg; range difference remains explicit. Cuff-pressure display 0–299 mmHg is separate |
| Clinical validation | A&D UK claims ESH 2010 validation; Medaval identifies the UK BIHS recommendation as manufacturer-declared equivalence to the UA-651 and says the equivalence study is unpublished. The US Validate BP listing covers UA-611 under ANSI/AAMI/ISO 81060-2:2018 with different cuff options; this does not establish direct validation of the supplied UK cuff configuration | STRIDE BP lists an exact-model diabetes study using ANSI/AAMI/ISO 2013, published in 2018, and adult acceptance by equivalence to BP A100. Published Beime study abstract reports 85 diabetic participants aged 56–88 and passing both protocol criteria; this does not establish every population in broad maker claims. Registry lists 22–42 and 32–52 cm validated cuffs |
| Features | Irregular heartbeat indicator, pressure progress bar, WHO classification indicator, stored-reading average and automatic power-off; irregular heartbeat indication is not a specific AFib diagnosis | Pulse Arrhythmia Detection indicates pulse irregularities, not a separate AFib algorithm or ECG. Cuff-fit and arm-movement indicators, coloured classification scale and low-battery warning; automatic switch-off after approximately one minute |
| Cuff | ||
| Cuff fits | 22–32 cm | – |
| Cuff | Supplied latex-free and metal-free SlimFit cuff fits 22–32 cm; optional large cuff fits 31–45 cm, sold separately; UK manual says this model is not designed for a small cuff | Exact guide lists S 17–22, M 22–32, M-L 22–42, L 32–42 and L-XL 32–52 cm cuffs and optional preformed Easy cuffs. Recovered support record does not establish the supplied size, so headline cuff range is omitted. Guide describes removable bladder and hand-washable cuff cover; do not wash bladder |
| Connections and memory | ||
| Users | – | 2 |
| Readings stored | 30 | 99 per user (better) |
| Bluetooth and app | No | No |
| Memory | Last 30 blood pressure and pulse measurements, with stored-reading average; no separate user memories listed | User switch selects one of two separate histories, each storing 99 dated readings. First recall shows average of all stored values, followed by individual history. Oldest overwritten when full. All values for selected user can be cleared, but individual stored values cannot; a newly displayed result can be excluded before storage. History survives battery replacement while clock requires resetting |
| App | No Bluetooth; readings can be recorded manually | USB PC link to Microlife Blood Pressure Analyzer+ using Mini-B 5-pin connector. Computer controls device during connection. No Bluetooth or mobile-app transfer. Current software compatibility must be checked separately rather than inferred from old CDs |
| Power | Four AA 1.5 V batteries; maker claims approximately 700 measurements with LR6 alkaline batteries or 200 with R6P manganese batteries at 180 mmHg and 23°C. UA-611 has no DC socket; the optional adapter in the shared manual applies only to UA-651 | Four 1.5 V AA alkaline cells; approximately 920 measurements with new batteries, without a separate MAM-cycle count. Optional Microlife DC 6 V, 600 mA adapter stops battery-current use when connected. NiMH cells supported but require external charging |
| Design | ||
| Display details | Systolic pressure, diastolic pressure and pulse shown with battery, irregular heartbeat and pressure/classification indicators | LCD with date/time and user indicator, ON/OFF, memory and time buttons, separate user and 1/3 MAM switches. USB and DC adapter sockets. IP20 |
| Size | Approximately 96 × 68 × 130 mm (width × height × depth); approximately 230 g excluding batteries | 143 × 85 × 58 mm; 368 g including batteries in exact guide and global support |
| In the box | UA-611 monitor, 22–32 cm SlimFit cuff, instruction manual and four AA batteries in the UK pack | Exact guide allows regional packages without cable or download voucher; complete original supplied bundle unresolved. Verified global archived specification/support record serves both resource types. English guide includes Greek regional guarantee wording; this is not a worldwide warranty claim |
More comparisons
- A&D Medical UA-611 vs A&D Medical UA-611Plus
- A&D Medical UA-611 vs Beurer BM 54
- A&D Medical UA-611 vs Rossmax AU941f
- A&D Medical UA-611 vs Rossmax AX356f
- A&D Medical UA-611 vs Beurer BM 23
- A&D Medical UA-611 vs Beurer BM 25
- A&D Medical UA-611 vs Beurer BM 27
- A&D Medical UA-611 vs Beurer BM 28
- A&D Medical UA-611 vs Beurer BM 35
- A&D Medical UA-611 vs Beurer BM 38
- A&D Medical UA-611 vs Beurer BM 51 easyClip
- A&D Medical UA-611 vs Beurer BM 58
- A&D Medical UA-611 vs Microlife BP 3AG1
- A&D Medical UA-611 vs Microlife BP 3AS1-2
- A&D Medical UA-611 vs Microlife BP A1 Easy
- A&D Medical UA-611 vs Microlife BP A2 Basic